WUHAN MACHINE EQUIPMENT CO LTD

 

WME >> Medical Material >> Face Mask

 

Face Mask

H.S.6307 9000 10

 

Specification Standard
Grade / Class
filtration efficiency face fitting tightness splash resistance pressure min order qty Note Photo
N95 sterile grade II GB19083 grade II
higher than EN14683 type II
≥99% required 10.7kPa

0.1 million

medical use, individual sterile packing.
with CE & FDA certification.

N95 sterile grade I GB19083 grade I
≥95% required 10.7kPa

0.1 million

medical use, individual sterile packing.
with CE & FDA certification.

non-woven face mask 3-layer YY/T0969
EN14683 type I
≥95% not required not required 0.5 million medical use,
with CE & FDA certification
KN95 GB2626
EN149 class FFP2
≥95% required not required 0.1 million civil use,
with CE & FDA certification

 

 

 

 

filtered anti-particle mask

+ now there is supply for the marked +

China standard GB2626
Class KN90 KN95 + KN100
Particle Filtration Efficiency (PFE) ≥90% ≥95% ≥99.97%
face fitting tightness required required required
splash resistance pressure not required not required not required
breather valve optional optional optional
application dustproof dustproof dustproof

 

 

European standard EN149
Class FFP1 FFP2 + FFP3
Particle Filtration Efficiency (PFE) ≥80% ≥94% ≥97%
face fitting tightness required required required
splash resistance pressure not required not required not required
breather valve optional optional optional
application dustproof dustproof dustproof

 

 

 

 

 

medical face mask

+ now there is supply for the marked +

China standard YY/T0969 YY0469 GB19083
  non-woven face mask 3-layer +   not sterile sterile
grade     I + II + III I / N95 / KN95 + II / N95 / KN95 + III
filtration efficiency     ≥95% ≥99% ≥99.97% ≥95% ≥99% ≥99.97%
face fitting tightness not required not required required required required required required required
splash resistance pressure not required not required 10.7kPa 10.7kPa 10.7kPa 10.7kPa 10.7kPa 10.7kPa
breather valve     not allowed not allowed not allowed not allowed not allowed not allowed
application definite patient, suspected patient definite patient, suspected patient   clinical use. protect medical staff from airborne respiratory infectious diseases, but can not be used for isolated Intensive Care Unit     clinical use. protect medical staff from airborne respiratory infectious diseases  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

European standard EN14683
Class type I + type II + type IIR
Bacterial Filtration Efficiency (BFE) ≥95% ≥98% ≥98%
Splash resistance pressure not required not required ≥16kPa
face fitting tightness not required required required
application

type I medical face mask should be only used for patients and other persons to reduce the risk of spread of infections particularly in epidemic or pandemic situation.

type I masks are not intended for use by healthcare professionals in an operating room, or in other medical settings with similar requirements.

   

 

 

 

Face Mask | Face Shield | Safety Goggles | Ventilator | Isolation Gown | Latex Gloves

Infrared Thermometer | COVID-19 Test Kit


WUHAN MACHINE EQUIPMENT CO LTD © 2020